<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15180</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: remove plate from picker (plate smaller than expected)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check box loading and spec, as for operator.
Check PZ for stalling, binding, stepper driver damage.
Check load ramp sensor, cable, (command "ramp" f/w 2.25)
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
"Clear" or "plate removed" will cause the plate to drop.
Lift bridge and secure, open front door and remove plate from picker,
</text></DescriptionText>
<DescriptionText><text>
close machine and select "plate removed" or "clear".
</text></DescriptionText>
<DescriptionText><text>
Check plate size in bay that this plate was picked from.
</text></DescriptionText>
<DescriptionText><text>
Check that the top of the box is level with the top of the drawer.
</text></DescriptionText>
<DescriptionText><text>
Check that the gap between the plates and the inside top edge of the box
is within 1/4".
</text></DescriptionText>
<DescriptionText><text>
Check that the correct box spec is loaded, (rim of box should be 1 1/2" wide).
</text></DescriptionText>
</OperatorAction>
<Cause>
At the end of a pick, if the upper load ramp sensor is not covered,
then this error is reported.   The final position will be affected by
queue_max_z see (err +41) and queue_jog_z
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_nlps.xml</LinkAddress><LinkTitle>NVS: al nlps</LinkTitle></Link>
<Link><LinkAddress>../nvs/alpos_cal_qmz.xml</LinkAddress><LinkTitle>NVS: alpos qmz</LinkTitle></Link>
<Link><LinkAddress>../nvs/alpos_cal_qjz.xml</LinkAddress><LinkTitle>NVS: alpos qjz</LinkTitle></Link>
<Link><LinkAddress>../error_messages/15181.xml</LinkAddress><LinkTitle>E_ALE_PLATE_TOO_LARGE</LinkTitle></Link>
<Link><LinkAddress>../commands/ramp.xml</LinkAddress><LinkTitle>Command: ramp</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:54 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/output/computer_to_plate/platesetter_3244/content/troubleshooting/15180.html</LinkAddress><LinkTitle>Other: Troubleshooting information</LinkTitle></Link>
</Links>
</Error>